Unreliable stability controls for wheeled furniture in patient-care areas
First to latest report 5 Nov 2013 — 6 Jun 2023
Reports that mention this concern
3
Times this concern has been raised
4
Stated actions linked to this concern
3
What this concern includes
Includes failures of controls dedicated to preventing unintended movement or unsafe access to wheeled chairs, beds and comparable wheeled furniture in patient-care areas, including removal from high-risk areas, securing or locking wheels, checking stability and addressing unsafe placement.
What is not included
Excludes general falls-risk assessment, supervision or post-fall response failures where wheeled furniture stability or placement is not the unsafe condition.
Excludes ordinary bed-brake failures limited to bed brakes when no comparable wheeled-furniture condition is identified; those belong to the narrower bed-brake concern.
Excludes wheelchairs, hoists, trolleys and clinical equipment where the assertion concerns their own named equipment-safety system rather than wheeled furniture used in patient-care areas.
Excludes isolated patient falls or unsafe furniture presence where no continuing deficiency in placement, stability or movement controls is asserted.
Trends
Reports over time
Reports mentioning this concern, over time
Reports about this concern issued each year.
* 2026 is projected from reports observed to 7 Sep 2026.
Most frequent recipients
Most frequent recipients
Reports about this concern sent to each recipient.
Blackpool Teaching Hospitals NHS Foundation Trust1
Care UK1
George Eliot Hospital NHS Trust1
NHS England1
Welsh Government1
NHS trust2
Devolved government1
Executive non-departmental public body1
Multi-service care provider1
Reports and published responses 3 reports
See individual reports that have raised this concern, and the actions taken in response
Berkshire
Concerns raised1
Failure to position a high-falls-risk resident’s bed appropriately
This report raised 3 other concerns. They are not shown here because they do not form part of this recurring concern.
No linked response statements
No respondent-stated action or position is linked to these concerns in the published data.
Warwickshire
Concerns raised2
Inaccessibility of inner-wheel locking mechanisms when beds are placed against walls
Failure to lock the inner wheels of beds
Linked responses
ArjoHuntleigh
NHS England
Stated actions An action is something a respondent says it has done, is doing, or plans to do in response to the concern raised.3
NHS England
Discuss the bed-wheel safety risk and identified guidance gaps with the MHRA.
NHS England
Work with occupational therapy and other stakeholders to develop new national resources for assessing and safely using beds.
ArjoHuntleigh
Recreate the incident in laboratory testing to assess brake operation, bed positioning, and movement conditions.
Respondent positions A position is what a respondent says about the concern when they do not describe a specific action.1
ArjoHuntleigh
No further action was considered necessary after post-market surveillance identified no similar incidents globally.
No action considered necessaryThe respondent said that no further action was needed.
Blackpool and the Fylde
Concerns raised1
Presence of wheeled chairs in areas accessible to elderly patients at significant risk of falls
This report raised 1 other concern. They are not shown here because they do not form part of this recurring concern.
No linked response statements
No respondent-stated action or position is linked to these concerns in the published data.
Actions and positions describe what organisations say in published responses. Implementation is not independently verified.