Recipient

Dolby Vivisol

First report 24 Nov 2014•Latest report 24 Nov 2014

Recipient record

Reports, concerns and published responses

Private and voluntary organisations · Company. This page brings together reports naming this recipient and response statements clearly connected to concerns raised in those reports.

Reports
1

Naming this recipient

Published responses
100%

Found for named reports

Concerns addressed
3

Across all linked responses

Stated actions
7

Described in responses

Reports over time

Reports over time

Reports naming this recipient by issue year.

Evidence profile

Report topics

Share of this recipient’s reports compared with all other recipients.

100%published responses found
7stated actions described

Topic comparisons are not available in the current evidence snapshot.

Concerns and recipient responses

Statements from Dolby Vivisol linked to the concerns in each report. Select any concern, action or position to view the source wording.

  1. Surrey

    AI-generated summary

    Gaenor Moore · Prevention of Future Deaths report

    This summary was generated using AI from the published report. Please read the original report for the complete account.

    Report summary

    Gaenor Moore, who had chronic obstructive pulmonary disease and required an oxygen concentrator with humidifier, became breathless, deteriorated and died at her residential care home after the humidifier cap was not properly engaged, preventing oxygen flow to her nasal cannula. Concerns included the absence of a visual or audible alarm to indicate loss of oxygen flow and training and literature that did not explain the implications of failing to properly engage the humidifier cap.

    Read the report on judiciary.uk

    Source evidence

    How this individual concern was interpreted

    PFD Monitor created a concise, searchable interpretation from the report wording shown below. The report was sent to Dolby Vivisol; that does not assign responsibility.

    PFD Monitor interpretation

    Failure to properly engage the humidifier screw cap, causing loss of oxygen flow to the nasal cannula

    Wider context from the report

    “• The lack of oxygen flow to the nasal cannula as a result of the screw cap to the humidifier not being properly engaged. • Absence of a visual or audible alarm on concentrator machine (product number INV-IRC5PO2AWN) to indicate the loss of oxygen flow to the nasal cannula when the screw cap to the humidifier (manufactured by Salter Labs) was tightened and cross threaded. • Accompanying training and literature did not reference the implications to oxygen flow in the event of failing to properly engage the screw cap to the humidifier. ”
    Open source report

    Source evidence

    How this individual concern was interpreted

    PFD Monitor created a concise, searchable interpretation from the report wording shown below. The report was sent to Dolby Vivisol; that does not assign responsibility.

    PFD Monitor interpretation

    Absence of a visual or audible alarm indicating loss of oxygen flow to the nasal cannula

    Wider context from the report

    “• The lack of oxygen flow to the nasal cannula as a result of the screw cap to the humidifier not being properly engaged. • Absence of a visual or audible alarm on concentrator machine (product number INV-IRC5PO2AWN) to indicate the loss of oxygen flow to the nasal cannula when the screw cap to the humidifier (manufactured by Salter Labs) was tightened and cross threaded. • Accompanying training and literature did not reference the implications to oxygen flow in the event of failing to properly engage the screw cap to the humidifier. ”
    Open source report

    Source evidence

    How this individual concern was interpreted

    PFD Monitor created a concise, searchable interpretation from the report wording shown below. The report was sent to Dolby Vivisol; that does not assign responsibility.

    PFD Monitor interpretation

    Failure of accompanying training and literature to explain the oxygen-flow implications of improper humidifier screw-cap engagement

    Wider context from the report

    “• The lack of oxygen flow to the nasal cannula as a result of the screw cap to the humidifier not being properly engaged. • Absence of a visual or audible alarm on concentrator machine (product number INV-IRC5PO2AWN) to indicate the loss of oxygen flow to the nasal cannula when the screw cap to the humidifier (manufactured by Salter Labs) was tightened and cross threaded. • Accompanying training and literature did not reference the implications to oxygen flow in the event of failing to properly engage the screw cap to the humidifier. ”
    Open source report

    Source evidence

    How this respondent action was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Communicate literature amendments to relevant staff and reinforce them during future patient and carer installation training.

    Verbatim wording from the response

    “3.2 The Company is actively liaising with Invacare (UK) Limited in relation to amendments proposed to their current instructions, which will warn about the potential effect of a failure to properly fasten a humidifier cap to its oxygen concentrator. The correspondence with Invacare is currently on-going, although I am told that Invacare proposes to update its instructions within the coming months. Upon receiving the final update from Invacare we will correspondingly review and/or update our instructions and training material.”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 3 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent action was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Submit finalized literature amendments to NHS contract managers for approval.

    Verbatim wording from the response

    “3.3 Once all draft amendments to current literature have been finalised, the proposed amendments will be sent as soon as possible to NHS contract managers for approval.”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 3 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent action was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Review and update company instructions and training materials after receiving manufacturers’ finalized amendments.

    Verbatim wording from the response

    “3.1 The Company is actively liaising with Salter Labs which manufactures the humidifier. Salter Labs has proposed additional wording on the product instructions in order to avoid leaks, and warn about the potential effect of a leak on the oxygen supply. The Company’s correspondence with Salter Labs is currently on-going, although I am informed by Salter Labs that updated labels will be attached to relevant products manufactured after 15 February 2015. Upon receiving the update from Salter Labs we will correspondingly review and/or update our instructions and training material.”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 3 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent action was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Liaise with Invacare about revised instructions warning of oxygen-flow effects when humidifier caps are improperly fastened.

    Verbatim wording from the response

    “3.2 The Company is actively liaising with Invacare (UK) Limited in relation to amendments proposed to their current instructions, which will warn about the potential effect of a failure to properly fasten a humidifier cap to its oxygen concentrator. The correspondence with Invacare is currently on-going, although I am told that Invacare proposes to update its instructions within the coming months. Upon receiving the final update from Invacare we will correspondingly review and/or update our instructions and training material.”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 3 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent action was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Modify humidifier literature to explain incorrect connection risks and emphasise confirming oxygen flow from the nasal cannula.

    Verbatim wording from the response

    “It is proposed that the humidifier leaflet will be modified to provide increased awareness of the impact caused by failure to connect the humidifier bottle correctly. Also there will be greater emphasis on the need to confirm the flow of oxygen from the nasal cannula. These enhancements will be reinforced during the patient/carer training provided by the Dolby Vivisol technicians.”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 3 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent action was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Distribute approved updated literature to current and future equipment users, highlighting amendments for current humidifier patients.

    Verbatim wording from the response

    “3.4 When approval is obtained from the NHS contract managers, the updated literature will be sent to all current and future Equipment users. The amendments will be specifically highlighted to current humidifier patients.”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 3 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent position was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Equipment manufacture and design concerns should be addressed by the relevant manufacturers, Invacare and Salter Labs.

    Verbatim wording from the response

    “As stated above, the Company cannot respond on points relating to the manufacture or design of the Equipment. Concerns about these issues should properly be addressed by the manufacturer of the oxygen concentrator and/or humidifier (Invacare (UK) Limited and Salter Labs respectively).”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 2 · response
    Published 24 November 2014

    Open published response

    Source evidence

    How this respondent position was interpreted

    PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

    PFD Monitor interpretation

    Equipment manufacture and design concerns fall outside the company’s functions, so it cannot respond to them.

    Verbatim wording from the response

    “As stated above, the Company cannot respond on points relating to the manufacture or design of the Equipment. Concerns about these issues should properly be addressed by the manufacturer of the oxygen concentrator and/or humidifier (Invacare (UK) Limited and Salter Labs respectively).”

    Source location

    2014-0512-Response-by-Dolby-Vivsol
    Page 2 · response
    Published 24 November 2014

    Open published response
Back to top

Published response patterns

Compared with other recipients in reports included in PFD Monitor

Describes published response evidence, not performance.

Published responses found

100%
100%All other recipients 58%
0%100%

How actions were described at the time

This respondent
29%71%
All other recipients
47%25%27%<1%<1%
  • Completed
  • In progress
  • Planned
  • Unclear
  • Partially completed

Statuses reflect what recipients said at the time. PFD Monitor does not verify whether actions happened.

Types of action described in responses

Percentages use all actions described by each group. An action may have more than one type, so percentages do not total 100%.

Information checked against published PFD reports and official responses · Data reviewed 7 Sep 2026 · About data quality and limitations

Data last updated 7 September 2026