Issued 7 Mar 2018•Inner West London

Report record

Published report and response evidence

This page connects the concerns raised in this report with statements found in recipients’ published responses. A link shows a clear evidence connection; it does not assign responsibility.

View original report
Concerns
13

Raised in this report

Recipients
5

Named on the report

Responses found
3

Of 5 recipients

Stated actions
17

Described in responses

Source document

Full report text

This is the full text from the original published report.

Open published report

Concerns and recipient responses

Select any concern, action or position to view the source wording.

Report evidence summary

Concerns raised13

  1. Failure to provide accessible appliance registration for people with limited computer literacy
  2. Delays in launching appliance repair or withdrawal campaigns
    Part of recurring concern: Unreliable product safety recall and remediation processes
  3. Failure to make linked fire alarms a contractual requirement for telecare clients
    Part of recurring concern: Unreliable fire-safety protection for telecare clientsPart of recurring concern: Unreliable telecare service safety controls
Responses linked to these concerns

Each statement is shown once, even when linked to more than one concern.

Actions described in response An action is something a recipient says it has done, is doing, or plans to do in response to a concern raised.8

  1. Action

    Improve businesses’ product-recall processes through Office-led work.

    Stated by Department for Business, Energy & Industrial StrategyStated in progressThe respondent said that this action was in progress when they made their response on 18 June 2018.
  2. Action

    Advise consumers to register new and second-hand electrical appliances through the recalls website for direct recall notifications.

    Stated by Department for Business, Energy & Industrial StrategyStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.
  3. Action

    Publish and implement the PAS 7100 Code of Practice for consumer product-safety recalls and corrective action.

    Stated by Department for Business, Energy & Industrial StrategyStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.

Respondent positions A position is what a recipient says about a concern when it does not describe a specific action.6

  1. Position

    Manufacturers are responsible for ensuring product safety and taking corrective action when safety issues are identified.

    Stated by Department for Business, Energy & Industrial StrategyRedirects responsibilityThe respondent said that another organisation was responsible for deciding or taking action.

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure to provide accessible appliance registration for people with limited computer literacy

Wider context from the report

“3. That any such campaign be also targeted at those who are less computer literate and consideration be given as to how to address their needs in relation to registration. ”

Is this part of a recurring concern?

No recurring-concern membership is currently published.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Delays in launching appliance repair or withdrawal campaigns

Wider context from the report

“1. That it simply took too long for Whirlpool UK to launch the repair/withdrawal campaign. ”

Is this part of a recurring concern?

Yes — Unreliable product safety recall and remediation processes.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure to make linked fire alarms a contractual requirement for telecare clients

Wider context from the report

“8. That telecare systems providers and WWA in particular, insist that their clients, who by definition are vulnerable, have linked fire alarms as a contractual requirement for both new and existing clients in the same way that such providers insist on the provision to them by the client of keys to the clients’ homes. ”

Is this part of a recurring concern?

Yes — Unreliable fire-safety protection for telecare clients; Unreliable telecare service safety controls.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure to escalate fire-alarm activations to the fire brigade within 30 seconds

Wider context from the report

“7. That telecare system operators and WWA in particular, apply the British Standards Institute requirement to call for the help of the fire brigade after 30 seconds maximum of trying to contact a client if the client’s fire alarm goes off. ”

Is this part of a recurring concern?

Yes — Failure of fire detection systems to reliably alert and trigger emergency response; Failure to take timely escalation action when safety thresholds are breached; Unreliable telecare service safety controls.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Artificially differentiated fire-safety treatment of watch-only and wider telecare clients

Wider context from the report

“4. That there is an artificial distinction between service users and clients who are “watch” only services, and those with wider telecare support. Either type of client would be vulnerable to fire. ”

Is this part of a recurring concern?

Yes — Unreliable fire-safety protection for telecare clients.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure to visibly flag unlinked fire alarms in client records

Wider context from the report

“12. That telecare systems providers and WWA in particular, highlight on the front screen of the client details, if that client has an unlinked fire alarm, until such a time as the unlinked alarm is replaced by a linked one, so as to alert call responders that sounds heard in the back ground or call may represent an activated fire alarm and thus the fire brigade may need to be called to the client’s home by the call responder. ”

Is this part of a recurring concern?

Yes — Unreliable smoke-alarm interlinking and status information for vulnerable people; Unreliable telecare service safety controls.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Unlinked household fire alarms in telecare users' homes

Wider context from the report

“5. That users of telecare systems have the fire alarms in their homes directly linked to the telecare systems. ”

Is this part of a recurring concern?

Yes — Unreliable fire-safety protection for telecare clients; Unreliable smoke-alarm interlinking and status information for vulnerable people.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure to identify and replace unlinked fire alarms in a timely and auditable manner

Wider context from the report

“9. That telecare systems providers and WWA in particular, take active steps to identify clients without linked fire alarms and arrange for them to be replaced with linked fire alarms and that this should be done in a timely and auditable fashion. ”

Is this part of a recurring concern?

Yes — Unreliable fire-safety protection for telecare clients; Unreliable smoke-alarm interlinking and status information for vulnerable people; Unreliable telecare service safety controls.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Lack of working relationships with local fire brigades to facilitate client home fire-risk assessments

Wider context from the report

“13. That telecare systems providers and WWA in particular, develop working relationships with their local fire brigades to facilitate fire risk assessments visits to the homes of the clients by the fire brigade being offered to telecare clients and accepted by them. ”

Is this part of a recurring concern?

Yes — Unreliable fire-safety protection for telecare clients.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Inadequate staff training on standards-compliant fire-alarm response

Wider context from the report

“10. That telecare systems providers and WWA in particular, train their staff on the appropriate response to the activation of a fire alarm and that this should be according to the standards laid down by the British Standards Institute. ”

Is this part of a recurring concern?

Yes — Failure to ensure staff competence in fire safety and evacuation; Unreliable telecare service safety controls.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure to train staff to recognise and escalate linked and unlinked fire-alarm sounds

Wider context from the report

“11. That telecare systems providers and WWA in particular, train their staff as to what fire alarm activation sounds like whether from a linked or unlinked alarm and that they should call the fire brigade appropriately if they are heard by the responder to be activated. ”

Is this part of a recurring concern?

Yes — Failure to ensure staff competence in fire safety and evacuation; Unreliable fire-safety protection for telecare clients; Unreliable telecare service safety controls.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Lack of a central appliance-owner registration and contact mechanism

Wider context from the report

“2. That there should be a safety campaign encouraging owners of appliances to register their details through a central portal such as AMBIA so that if concerns about an appliance arise they may be promptly contacted. ”

Is this part of a recurring concern?

No recurring-concern membership is currently published.

Open source report

Source evidence

How this individual concern was interpreted

PFD Monitor created a concise, searchable interpretation from the report wording shown below. Response links show a clear evidence connection; they do not assign responsibility.

PFD Monitor interpretation

Failure of telecare systems to maintain communication throughout clients' properties

Wider context from the report

“6. That telecare systems be organised such that a client operating a pendant alarm can talk with the responder no matter where the client is within their property such as to allow a client with mobility problems to be in proper communication with their telecare system operator at all times. ”

Is this part of a recurring concern?

Yes — Unreliable telecare service safety controls.

Open source report

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Improve businesses’ product-recall processes through Office-led work.

Verbatim wording from the response

“The Office for Product Safety and Standards is leading work to improve businesses product recall processes. My Department commissioned the British Standards Institution (BSI) to create a new Code of Practice on product recalls (PAS 7100 Code of practice on consumer product safety related recalls and other corrective action). This was launched on 7 March. It guides businesses and regulators through the process of planning for and handling a product safety incident for non-food consumer products. The Code of Practice also sets out for Local Authorities the guidance and advice they should be making available to enable businesses to meet their legal responsibilities and act in the public interest.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 3 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Advise consumers to register new and second-hand electrical appliances through the recalls website for direct recall notifications.

Verbatim wording from the response

“In October 2016 the Government set up a new central recalls website to provide consumers with information on recalls of all electrical goods and other products. The recalls website was upgraded in June 2017 and provides a single portal for access to information about current product recalls, drawing on UK and international recall information. It provides a centralised up to date source of trusted advice and information that users can interact with. Government also advises consumers to register their electrical appliances, whether new or second-hand, with the manufacturer via the recalls website, so they can be informed directly by the manufacturer should a recall or other corrective action subsequently be required. Future upgrades to the website expected by 2019 will involve the building of an extensive data hub of all corrective action and recall programmes affecting consumer products.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Publish and implement the PAS 7100 Code of Practice for consumer product-safety recalls and corrective action.

Verbatim wording from the response

“The Office for Product Safety and Standards is leading work to improve businesses product recall processes. My Department commissioned the British Standards Institution (BSI) to create a new Code of Practice on product recalls (PAS 7100 Code of practice on consumer product safety related recalls and other corrective action). This was launched on 7 March. It guides businesses and regulators through the process of planning for and handling a product safety incident for non-food consumer products. The Code of Practice also sets out for Local Authorities the guidance and advice they should be making available to enable businesses to meet their legal responsibilities and act in the public interest.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 3 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Maintain lifecycle product-safety policies covering pre-market assessment, post-sale monitoring, incident investigation, risk assessment, hazard reporting and field corrective-action decisions.

Verbatim wording from the response

“Whirlpool has a comprehensive set of policies, procedures, and guidelines in place for field monitoring, field safety investigations, analysis, risk assessment, and reporting potential safety hazards associated with its products in order to inform an expeditious decision on a field corrective action. These systems have been developed and refined over decades, and Whirlpool keeps those systems under review as part of its commitment to continual improvement.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 1 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Channel reported incidents through a dedicated UK team for consistent initial investigation and escalate safety-related cases for product-safety-engineer review.

Verbatim wording from the response

“When this initial contact occurs, every effort is made to gather as much information as possible regarding the appliance, the consumer, and the alleged incident. This allows us to both assist the consumer wherever we can, and it also allows us to investigate the matter in more depth.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Promote consumer appliance registration through online and offline registration, trained telephone advisors, product stickers, marketing materials and annual registration initiatives.

Verbatim wording from the response

“Whirlpool continues to be a prominent advocate within AMDEA both to promote consumer awareness of the scheme and to communicate to consumers why registration is so important. It features on our websites and across our consumer literature. We are proud to have the highest consumer appliance registration rate in the industry and one of the largest consumer databases.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 3 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Operate senior-leadership oversight through a designated Executive Safety Committee responsible for deciding whether potential product-safety risks require field corrective action.

Verbatim wording from the response

“Whirlpool's approach to product safety governance starts with senior leadership oversight, with a specially designated Executive Safety Committee. The membership of Whirlpool's Executive Safety Committee includes members of the Whirlpool senior leadership team from a cross-section of the company. This team is responsible for the decisions regarding the need to undertake field corrective actions for potential product safety risks that have been identified.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 1 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Continue industry and stakeholder discussions to improve registration awareness, portal usability and access for vulnerable consumers.

Verbatim wording from the response

“Whirlpool continues to pursue initiatives to improve registration rates both for its own products, and within the industry generally. Over the past year Whirlpool has engaged in dialogue with key stakeholders including consumer advocacy groups and government agencies to consider options for addressing this important issue. For example, Whirlpool is actively leading discussions within the industry on how to improve consumer awareness of the ‘Register My Appliance’ site, make the site easier to navigate, and make the importance of registration clearer. In recent consumer communications, Whirlpool has also worked with consumer advocacy groups and charities to encourage registrations among more vulnerable members of society who may prefer human interaction to online registration.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 3 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent position was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Manufacturers are responsible for ensuring product safety and taking corrective action when safety issues are identified.

Verbatim wording from the response

“As you know, the dishwasher that started the fire that caused Mrs Griffin’s death was a model that was subject to a corrective action programme as it had been identified as representing a safety risk. The manufacturer is responsible for ensuring the safety of their product and for taking corrective action when safety issues are identified. Sadly, in this case, Mrs Griffin’s dishwasher was not identified by Whirlpool and had not been repaired or replaced.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent position was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

The product-recall Code of Practice provides methods for reaching consumers without online access, addressing accessibility concerns.

Verbatim wording from the response

“The Office for Product Safety and Standards is leading work to improve businesses product recall processes. My Department commissioned the British Standards Institution (BSI) to create a new Code of Practice on product recalls (PAS 7100 Code of practice on consumer product safety related recalls and other corrective action). This was launched on 7 March. It guides businesses and regulators through the process of planning for and handling a product safety incident for non-food consumer products. The Code of Practice also sets out for Local Authorities the guidance and advice they should be making available to enable businesses to meet their legal responsibilities and act in the public interest.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 3 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent position was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

The central recalls website provides a single source of recall information and enables consumers to register appliances for direct notifications.

Verbatim wording from the response

“In October 2016 the Government set up a new central recalls website to provide consumers with information on recalls of all electrical goods and other products. The recalls website was upgraded in June 2017 and provides a single portal for access to information about current product recalls, drawing on UK and international recall information. It provides a centralised up to date source of trusted advice and information that users can interact with. Government also advises consumers to register their electrical appliances, whether new or second-hand, with the manufacturer via the recalls website, so they can be informed directly by the manufacturer should a recall or other corrective action subsequently be required. Future upgrades to the website expected by 2019 will involve the building of an extensive data hub of all corrective action and recall programmes affecting consumer products.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent position was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Indesit responded promptly to the information available during the DWF Series 3 dishwasher safety campaign.

Verbatim wording from the response

“The Coroner raised concerns over the length of timing of the safety campaign for the DWF Series 3 Dishwashers. We welcome the opportunity to provide some context to that safety campaign and Whirlpool's product safety processes.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 1 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent position was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Responsibility for the matter rests with trading standards departments run by local authorities.

Verbatim wording from the response

“I would like to take this opportunity to advise you that the Chartered Trading Standards Institute is a private company and professional body for trading standards officers, as such this matter is not something that we are able to get involved with as we have no powers, this would be a matter for trading standards departments that are run by local authorities.”

Source location

2018-0072-Response-by-CTSI
Page 1 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent position was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

The matter falls outside the organisation’s authority because it has no powers to intervene.

Verbatim wording from the response

“I would like to take this opportunity to advise you that the Chartered Trading Standards Institute is a private company and professional body for trading standards officers, as such this matter is not something that we are able to get involved with as we have no powers, this would be a matter for trading standards departments that are run by local authorities.”

Source location

2018-0072-Response-by-CTSI
Page 1 · response
Published 18 June 2018

Open published response

Other statements in published responses

These actions and other statements could not be clearly connected to one concern in this report.

Recipient-stated actions An action is something a recipient says it has done, is doing, or plans to do in response to a concern raised.9

  1. 1

    Work with local authorities and businesses to clarify risk-notification criteria and improve regulatory support.

    Stated by Department for Business, Energy & Industrial StrategyStated plannedThe respondent said that this action was planned when they made their response on 18 June 2018.
  2. 2

    Establish the Office for Product Safety and Standards to lead the upgraded product safety system.

    Stated by Department for Business, Energy & Industrial StrategyStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.
  3. 3

    Meet Whirlpool UK’s General Manager to discuss the company’s product-recall and corrective-action approach.

    Stated by Department for Business, Energy & Industrial StrategyStated plannedThe respondent said that this action was planned when they made their response on 18 June 2018.
  4. 4

    Operate a central recalls website providing consumers with current product-recall information and access to trusted safety advice.

    Stated by Department for Business, Energy & Industrial StrategyStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.
  5. 5

    Build an extensive data hub covering corrective-action and recall programmes affecting consumer products.

    Stated by Department for Business, Energy & Industrial StrategyStated plannedThe respondent said that this action was planned when they made their response on 18 June 2018.
  6. 6

    Operate an independent Global Product Safety Team separately from product-development, engineering and commercial teams to make safety-focused decisions.

    Stated by Hotpoint UK Appliances LimitedStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.
  7. 7

    Centralize machine inspection reports and categorize investigated incidents in a searchable database to identify, monitor and assess potential field-safety hazards.

    Stated by Hotpoint UK Appliances LimitedStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.
  8. 8

    Published the workforce survey online for public access.

    Stated by Chartered Trading Standards InstituteStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.
  9. 9

    Conducted a workforce survey of trading standards services in England and Wales.

    Stated by Chartered Trading Standards InstituteStated completedThe respondent said that this action was complete when they made their response on 18 June 2018.

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Work with local authorities and businesses to clarify risk-notification criteria and improve regulatory support.

Verbatim wording from the response

“I have asked the Office for Product Safety and Standards to work with local authorities and businesses to clarify expectations regarding the criteria for triggering a notification of risk to regulators, and how this can be done more effectively with Office support in order to improve levels of consumer protection in the UK.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Establish the Office for Product Safety and Standards to lead the upgraded product safety system.

Verbatim wording from the response

“In January 2018, the Government announced an upgrade to the product safety system to be led by a new Office for Product Safety and Standards. I recognise the issues you have set out in your report and want to assure you that these are issues we have taken action on and will continue to be a focus for the work of the new Office for Product Safety and Standards.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Meet Whirlpool UK’s General Manager to discuss the company’s product-recall and corrective-action approach.

Verbatim wording from the response

“You may also wish to be aware that I will be meeting with the General Manager of Whirlpool UK in May regarding Whirlpool’s approach to product recall and corrective action.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 3 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Operate a central recalls website providing consumers with current product-recall information and access to trusted safety advice.

Verbatim wording from the response

“In October 2016 the Government set up a new central recalls website to provide consumers with information on recalls of all electrical goods and other products. The recalls website was upgraded in June 2017 and provides a single portal for access to information about current product recalls, drawing on UK and international recall information. It provides a centralised up to date source of trusted advice and information that users can interact with. Government also advises consumers to register their electrical appliances, whether new or second-hand, with the manufacturer via the recalls website, so they can be informed directly by the manufacturer should a recall or other corrective action subsequently be required. Future upgrades to the website expected by 2019 will involve the building of an extensive data hub of all corrective action and recall programmes affecting consumer products.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Build an extensive data hub covering corrective-action and recall programmes affecting consumer products.

Verbatim wording from the response

“In October 2016 the Government set up a new central recalls website to provide consumers with information on recalls of all electrical goods and other products. The recalls website was upgraded in June 2017 and provides a single portal for access to information about current product recalls, drawing on UK and international recall information. It provides a centralised up to date source of trusted advice and information that users can interact with. Government also advises consumers to register their electrical appliances, whether new or second-hand, with the manufacturer via the recalls website, so they can be informed directly by the manufacturer should a recall or other corrective action subsequently be required. Future upgrades to the website expected by 2019 will involve the building of an extensive data hub of all corrective action and recall programmes affecting consumer products.”

Source location

2018-0072-Response-by-Department-for-Business-Energy-Industrial-Strategy
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Operate an independent Global Product Safety Team separately from product-development, engineering and commercial teams to make safety-focused decisions.

Verbatim wording from the response

“Another important aspect of product safety governance at Whirlpool is the built-in system of checks and balances. Whirlpool has established an independent Global Product Safety Team which operates separately from product development, engineering, and commercial teams. The independence from the product development, engineering, and commercial teams allows this team to make unbiased decisions that are focused first on safety. This team has a direct link to the Whirlpool senior leadership team.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 1 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Centralize machine inspection reports and categorize investigated incidents in a searchable database to identify, monitor and assess potential field-safety hazards.

Verbatim wording from the response

“In some instances, the physical product may not be available or may not require a field replacement; however, the details of the report are still documented in our system and can be used qualitatively when an engineering investigation is performed.”

Source location

2018-0072-Response-by-Whirlpool-UK
Page 2 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Published the workforce survey online for public access.

Verbatim wording from the response

“On a separate matter you may be interested to hear that CTSI has recently conducted a workforce survey of trading standards services in England and Wales. This demonstrates the severe and deep cuts to trading standards services which in turn has led to a reduction in activity and prioritisation. A copy of the survey can be viewed at https://www.tradingstandards.uk/media/documents/news--policy/surveys/ctsi-workforce-survey-2017.pdf”

Source location

2018-0072-Response-by-CTSI
Page 1 · response
Published 18 June 2018

Open published response

Source evidence

How this respondent action was interpreted

PFD Monitor created a concise, searchable interpretation from the published response wording shown below.

PFD Monitor interpretation

Conducted a workforce survey of trading standards services in England and Wales.

Verbatim wording from the response

“On a separate matter you may be interested to hear that CTSI has recently conducted a workforce survey of trading standards services in England and Wales. This demonstrates the severe and deep cuts to trading standards services which in turn has led to a reduction in activity and prioritisation. A copy of the survey can be viewed at https://www.tradingstandards.uk/media/documents/news--policy/surveys/ctsi-workforce-survey-2017.pdf”

Source location

2018-0072-Response-by-CTSI
Page 1 · response
Published 18 June 2018

Open published response
Back to top

Information checked against the published report and official responses · Data reviewed 7 Sep 2026 · About data quality and limitations

Official responses located
3/5

Data last updated 7 September 2026