First reported 3 Jul 2017•Latest report 31 Oct 2023
Definition
What this concern includes
Includes failures of controls specifically dedicated to the safe operation of riser-recliner chairs in care settings, including control access restrictions, entrapment detection, user-safety features, risk assessment and associated protective measures where these directly address chair-operation hazards.
Not included
Excludes generic care-home risk assessment, staffing, training or equipment-management deficiencies unless they are specifically tied to riser-recliner chair safety.
Excludes failures involving other types of chairs, beds, hoists or lifting equipment unless the assertion explicitly concerns riser-recliner chair safety.
Excludes general falls, pressure-injury or resident-supervision concerns that do not identify a dedicated riser-recliner chair control failure.
Reports
2
Distinct published reports
Individual concerns
5
A report can raise multiple concerns
Date range
2017–2023
First to latest report issue date
Stated actions
8
Described in published responses
Reports over time
Reports over time
Reports about this concern issued each year.
* 2026 is projected from reports observed to 7 Sep 2026.
Most frequent recipients
Most frequent recipients
Reports about this concern sent to each recipient.
A. J. Way and Co. Ltd1
Care Quality Commission1
Department of Health and Social Care1
Health and Safety Executive1
National Trading Standards1
Recipient name withheld1
Yorkshire Care Equipment1
Company1
Consumer protection enforcement body1
Health and social care service regulator1
Ministerial department1
Workplace safety regulator1
Type not available1
Concerns and responses across reports
Only concerns grouped under this recurring concern are included. Select any concern, action or position to view the source wording.
Somerset
Concerns raised4
Unavailability of riser-recliner chairs with controls that limit unauthorised use
Failure to assess and mitigate the risk of cognitively impaired residents accessing riser-recliner chair controls
Health and safety risk from disabling riser-recliner chair controls at the mains
Risk of death to other residents from cognitively impaired residents operating riser-recliner chair controls
Responses linked to these concerns
Each statement is shown once, even when linked to more than one concern.
Actions described in response An action is something a respondent says it has done, is doing, or plans to do in response to the concern raised.7
Action
Process all future riser/recliner chair orders through Shackleton’s and fit supplied chairs with lockable handsets.
Stated by Aria Care GroupStated completedThe respondent said that this action was complete when they made their response on 6 November 2023.
Action
Work with residents and families to replace privately owned riser/recliner chairs lacking lockable handsets.
Stated by Aria Care GroupStated plannedThe respondent said that this action was planned when they made their response on 6 November 2023.
Action
Explore and develop a potentially universal lockable cover to restrict access to riser/recliner handset controls.
Stated by Aria Care GroupStated in progressThe respondent said that this action was in progress when they made their response on 6 November 2023.
Action
Use compatible Shackleton’s controls to reduce unauthorised access while universal covers are developed.
Stated by Aria Care GroupStated plannedThe respondent said that this action was planned when they made their response on 6 November 2023.
Action
Use generic and resident-specific risk assessments requiring safe chair positioning and electrical isolation where residents cannot independently control chairs.
Stated by Aria Care GroupStated completedThe respondent said that this action was complete when they made their response on 6 November 2023.
Action
Reduce riser/recliner chair use through a phased approach and purchase assessed-need furniture solely from Shackleton’s with lockable handsets.
Stated by Aria Care GroupStated plannedThe respondent said that this action was planned when they made their response on 6 November 2023.
Action
Notify the Office for Product Safety and Standards about the incident for consumer-product safety consideration.
Stated by Health and Safety ExecutiveStated completedThe respondent said that this action was complete when they made their response on 6 November 2023.
Respondent positions A position is what a respondent says about the concern when they do not describe a specific action.6
Position
A universal lockable handset cannot be supplied because riser/recliner chairs use different manufacturers, and some chairs are incompatible with available handsets.
Stated by Aria Care GroupUnable to actThe respondent said that a constraint prevented them from taking the relevant action.
Position
A universal lockable handset cover cannot provide an immediate short-term solution because development and trial may take two to three months.
Stated by Aria Care GroupUnable to actThe respondent said that a constraint prevented them from taking the relevant action.
Position
Consumer-product safety enforcement for chairs purchasable for domestic use normally falls to local-authority Trading Standards, not HSE.
Stated by Health and Safety ExecutiveRedirects responsibilityThe respondent said that another organisation was responsible for deciding or taking action.
Position
CQC cannot take further enforcement action because there is insufficient evidence linking the incident directly to a registered person.
Stated by Department of Health and Social CareUnable to actThe respondent said that a constraint prevented them from taking the relevant action.
Position
Service-user safety enforcement in registered care homes is outside HSE’s remit.
Stated by Health and Safety ExecutiveOutside remitThe respondent said that this matter was outside its role or authority.
Position
CQC is responsible for regulating safety, treatment and care matters involving service users in registered care homes.
Stated by Health and Safety ExecutiveRedirects responsibilityThe respondent said that another organisation was responsible for deciding or taking action.
North Yorkshire (West)
Concerns raised1
Lack of chair sensors to detect a foot in the mechanism
Responses linked to these concerns
Each statement is shown once, even when linked to more than one concern.
Actions described in response An action is something a respondent says it has done, is doing, or plans to do in response to the concern raised.1
Action
Fit sensor strips or protective screens beneath chair sides and backs where entrapment risk is identified.
Stated by AJ Way Co LtdStated completedThe respondent said that this action was complete when they made their response on 3 July 2017.
Respondent positions A position is what a respondent says about the concern when they do not describe a specific action.2
Position
Sensors are unsuitable for front legrest entrapment because the legrest flexes, so they cannot address the accident mechanism.
Stated by AJ Way Co LtdDisputes the concernThe respondent disagreed with part of the concern or the basis for it.
Position
Protective sensors are added only when retailers order them after identifying an entrapment risk.
Stated by AJ Way Co LtdRedirects responsibilityThe respondent said that another organisation was responsible for deciding or taking action.