Investigation and inquest
On 13 September 2018 I commenced an investigation into the death of Ava-May LITTLEBOY aged 3 years.
The investigation concluded at the end of the inquest, held with a jury, on 19 March 2020. The medical
cause of death was:
1a Traumatic Head Injury
The conclusion of the inquest was: Ava-May’s guardians paid for the use of a trampoline which exploded
following which she died
Circumstances of the death
Ava-May went to the beach at Gorleston with her family on 1 July 2018. She went on an inflatable
trampoline, which exploded, throwing her into the air. She died later that day in James Paget University
Hospital as a result of her injuries.
Questions for the Jury:
1a) When acquiring the inflatable trampoline was an operating/Instruction Manual relevant to the
trampoline obtained? NO
b) Was the trampoline checked by an independent third party before its use? NO
2. Was there an up to date and complete Risk Assessment in respect of the trampoline as at 1 July 2018?
NO
3. Was a procedure in place to safely manage the inflation of the trampoline (even when the site was open
to customers)? NO
4a) Did staff receive training in respect of working with the equipment and customers on site? SOME
b) Did staff receive training in respect of operating the trampoline? NO
5a) Were staff supervised whilst working on site? SOME OF THE TIME
b) Were children supervised by staff when going onto the trampoline SOME OF THE TIME
Coroner’s concerns
1. Evidence was heard that it is required a device will be inspected by an independent third party and,
provided it satisfies relevant requirements, it will be certified under the Amusement Device Inspection
Procedures Scheme (ADIPS) (or Pertexa Inflatable Play Equipment (PIPA) or another testing scheme or
method which demonstrates how such procedures equal or better the accepted best practice) as safe
to operate and a Declaration of Operational Compliance (DOC) will be issued. If the device is not
deemed fit to use, then the device is categorised according to the defect or concern raised which may
result in a DOC not being issued and the operator advised not to use the equipment until the defect has
been rectified.
The inflatable trampoline had been acquired in August/September 2017 and was inspected by an
independent company on 26 June 2018 (namely 4 days prior to the trampoline exploding). Concerns
were raised by the independent company with regard to no pre-use manufacturing paperwork being
available and that not all Tie Downs were being used. Evidence was heard that had the trampoline been
registered under ADIPS a Category A defect would apply, namely that the device is considered as being
of imminent danger to persons and that the device should not be used until those defects have been
rectified. As such, a DOC would not have been issued and it would have been clear that the trampoline
was not fit to be used.
However, as the trampoline had not been registered under ADIPS (or PIPA or an independent scheme),
the issues could not be categorised and it would not be recorded in any public domain that a DOC had
not been issued.
2. Further, there is no requirement that the relevant enforcing authority, for instance Health and Safety
Executive or the Local Authority is informed that the equipment is deemed unsafe to use.
3. The evidence also revealed that there is no legal requirement for an Operator to use either the ADIPS
or PIPA inspection process but can rely on an alternative form of scheme or method of their own
choosing to demonstrate the device is safe to use.